Description
UFH Heat Pump System Control Pack
Overview
A compact prefabricated pack designed to thermostatically control the temperature of water within an underfloor heating system. The kit includes a thermostatic mixing valve, an ERP rated 7 metre circulating pump, and a flow manifold connection tee piece which includes a ½” FBSP tapping that can be used for reading temperatures and pressures or as a connection point for the UFH overheat thermostat.
Features and Benefits
-
-
- The thermostatic unit gives excellent temperature stability particularly when return temperatures and mixed water temperatures are close to equal
- The system is designed to be fully flexible and can be fitted on either the left or right sides of the manifold, with the return at the top or bottom
- The mixing valve will function down to 25°C to ensure that initial warm-up and commissioning can be correctly carried out
- The side profile of the valve is reduced to allow easy fitting of the pack inside cabinets
- Features a temperature range from 25°C to 60°C to cater for all types of floor constructions
-
Specification
Hot temperature supply range: 60°C – 85°C
Adjustable temperature range: 25°C – 60°C
Maximum supply pressure: 6 bar
Factory set temperature range: 45°C +/- 2°C
Temperature stability +/-2°C
Connections: Mixing valve inlets ¾” FBSP
Manifold connections 1” MBSP